SetupReaderViewerOnline
Template
The template, selected via Setting > LOG-HC2 (*.mse), defines which
sensors the Reader reads out as standard or are displayed in Online. The
template sets the colour of the trace, the positioning of its axis (left, right)
and gives the sensors a name (“HUM, T1” is required to be displayed as
“outside temperature”, for example). Templates can be produced on the
basis of examples contained in Viewer (->34).
Example
The temperature curves are required to be blue and oriented on the right
hand axis in all display modes.
1. Assign right hand axis and blue colour shades to temperature in Viewer.
2. Save as template (Bluetemp.mse).
3. Generate new templates for Reader and Online: Select logger program
window, Settings LOG-HC2 > Template , enter new name and path
(Temperature.mse), then Open.
4. Open the still blank template (Temperature.mse) using .
5. Import the template that was created in Viewer (Bluetemp.mse).
Select the required sensors (tick in checkbox) in the Module column and
confirm with Accept.
6. Edit the displayed list: First select a sensor in the Module column and
then choose Edit.
7. Change the name “HUM, T1” to “Outside temperature”, and Accept.
8. Continue to make the necessary adjustments and confirm them with Accept.